Non-Preloaded Bolt Proof Strength Chart


As part of the Non-preloaded chapter for the Bolted connections (only ISO Metric), I made a quick chart. In the chart, you can obtain the proof load strength of the most typical bolt sizes (from M3 to M42), for regular and fine thread pitch.

The chart is divided in three sheets:

-ISO 898-1 for Steels and Alloy Steels

-ISO3506-1 for Stainless Steels.

-ISO 8839 for non-ferrous materials.

You have also two inputs per sheet, where you can control the safety factor/load factor, and a second one to control the shear/tensile ratio.

Click in the following link, and download the excel chart

https://mega.nz/#!DgJDFbpI!ALrjYCUnFxJElN5NkiTPB9kjYahifR8wwRqvTlj1gYo